| Computer # |
| 4967.
 | 21 | Mapping cardiac |B1+| field with B1+ prepared imaging Paulina Siuryte1, Markus Henningsson2, Christal van de Steeg-Henzen3, and Sebastian Weingärtner1 1TU Delft, Delft, Netherlands, 2Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden, 3Holland PTC, Delft, Netherlands Keywords: Heart, Artifacts, cardiac B1+ mapping, transmit field imaging Cardiac MRI at 3T offers gains in SNR, but is strongly affected by field inhomogeneities, including the transmit field B 1+. Mapping |B 1+| field around the heart is particularly challenging due to the presence of motion, and few techniques exist for robust imaging. Recently, Bloch-Siegert shift mapping was proposed for motion robust cardiac |B 1+| mapping, however, it requires long echo times making it more susceptible to artifacts. Here, we introduce a new preparation module for efficient |B 1+| mapping. The method shows 0.06% / 0.35% reduced noise variability in phantom and 0.61±0.35% / 0.89±0.63% in-vivo imaging, and visually improved map quality. |
| 4968.
 | 22 | Fast continuous 3D catheter balloon tracking for MRI-guided cardiac catheterization using 1D slice projection imaging with GRE stack of slices. Grzegorz Tomasz Kowalik1, Radhouene Neji1,2, Tracy Moon3, Nina Mellor3, Reza Razavi1, Kuberan Pushparajah1, and Sébastien Roujol1 1School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom, 2MR Research Collaborations, Siemens Healthcare Limited, Camberley, United Kingdom, 3Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom Keywords: Heart, MR-Guided Interventions An automated catheter tracking approach was developed for real-time continuous catheter visualization during MR-guided cardiac catheterization. 1D projection images are acquired for each slice of a stack providing fast 3D volume screening. These images are first collected in the absence of catheter to create an atlas on background signal across the breathing cycle. During catheter navigation, incoming images are matched to the best images of the atlas, which are then subtracted to suppress background signal. Finally, automated peak detection is applied to extract the catheter balloon location. The technique is successfully demonstrated during in-vitro and in one patient. |
| 4969.
 | 23 | Cardiac MRI at 3.0T in the presence of implantable cardioverter defibrillators (ICDs) Theresa Reiter1, Oliver M Weber2, Ingo Weiss3, and Wolfgang Rudolf Bauer1 1Medicine I, University Hospital Wuerzburg, Wuerzburg, Germany, 2Philips GmbH, Hamburg, Germany, 3Biotronik SE Co.KG, Berlin, Germany Keywords: Myocardium, Visualization Performing
a cardiac MRI in the presence of active cardiac implants remains a challenge
due to the extensive artifact burden caused by the implant. Sequence solutions
established at 1.5 T have yet to be transferred to a clinical use at 3T. In
this work, we use phantom and volunteer measurements in order to establish an
adapted 3T protocol for CINE with TFE and wideband LGE-PSIR sequences that
sufficiently suppress image artifacts caused by active implants. The first
clinical data show the feasibility of this protocol and its ability to detect
scar tissue in patients with implanted ICD. |
| 4970.
 | 24 | Real-time Automatic Passive Catheter Tracking During MR-guided Cardiac Catheterization Rohini Vidya Shankar1, Li Huang1, Radhouene Neji1,2, Grzegorz Kowalik1, Alexander Paul Neofytou1, Ronald Mooiweer1,2, Tracy Moon3, Nina Mellor3, Reza Razavi1, Kuberan Pushparajah1, and Sébastien Roujol1 1Biomedical Engineering, King's College London, London, United Kingdom, 2MR Research Collaborations, Siemens Healthcare Limited, Camberley, United Kingdom, 3Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom Keywords: Heart, MR-Guided Interventions, Tracking, Real-time MR-guided cardiac catheterization procedures
currently employ passive tracking approaches to follow the gadolinium-filled
catheter balloon during catheter navigation. This requires frequent manual
tracking and repositioning of the imaging slice, especially when the catheter
moves out-of-plane during the procedure. In this study, we developed a novel
MRI guidance approach that enables automatic real-time tracking of the catheter
balloon and repositioning of the imaging slice for continuous visualization of
the balloon during catheter navigation. We first demonstrate the proposed
approach in a phantom and subsequently present an initial evaluation in
patients. |
| 4971.
 | 25 | Quantification and evaluation of cardiac motion correction methods for hybrid PET/MRI Heeseung Lim1, Benjamin Wilk1,2, Gerald Moran3, Heather Biernaski1, Jonathan D. Thiessen1,2,4, and Frank S. Prato1,2,5 1Lawson Imaging, Lawson Health Research Institute, London, ON, Canada, 2Medical Biophysics, Western University, London, ON, Canada, 3Siemens Healthcare Limited, Oakville, ON, Canada, 4Medical Imaging, Western University, London, ON, Canada, 5Physics and Astronomy, Western University, London, ON, Canada Keywords: Heart, Cardiovascular Different motion correction methods for cardiac
imaging were compared with no motion correction and free-motion images on a
hybrid PET/MRI platform. These data were acquired in eight large animals five
days after induction of myocardial infarction. PET/MRI images were acquired
under different conditions of cardiac and respiratory motion: BodyCompass™,
XD-GRASP, ECG gated. Upon completion of in vivo imaging, the animal was
immediately euthanized within the scanner, and motion-free images were acquired.
Initial quantitative evaluation of the cardiac images showed variation in mean
and standard deviation values between the region of interest and different
motion correction methods. |
| 4972.
 | 26 | SENSE factor optimization for 2D RF based Reduced Field of View DWI on Cardiac at 3.0T Yang Wu1, Peng Sun2, Zhigang Wu2, Xiaoxiao Zhang2, Jing Zhang2, and Jiazheng Wang2 1Department of Medical Imaging, Wuhan Asia General Hosipital, Wuhan, China, 2Philips Healthcare, Beijing, China Keywords: Myocardium, Cardiovascular Diffusion
MRI delivers unique information about the heart without the use of external
contrast agents, Because of B0 inhomogeneity within the thorax and short
transverse relaxation durations, which cause substantial distortion and signal
loss, it has proven technically problematic. DWI with Zoom imaging with 2D RF
pulse (iZoom) could significantly minimize distortion, but it is still
vulnerable to field inhomogeneity when it is big. iZoom with SENSE could reduce
distortion and signal loss even further. An in vivo research on volunteers with
various SENSE factors revealed that combining iZoom with SENSE considerably
improves visual quality. |
| 4973.
 | 27 | Deep-learning-based Group-wise Motion Correction for Myocardial T1 Mapping Eyal Hanania1, Lilach Barkat1, Israel Cohen1, Haim Azhari1, and Moti Freiman1 1The Technion – Israel Institute of Technology, Haifa, Israel Keywords: Myocardium, Quantitative Imaging, Cardiac, Relaxation Diffuse myocardial diseases can be diagnosed using T1 mapping technique. The T1 relaxation parameter is computed through the pixel-wise model fitting. Hence, pixel misalignment resulted by cardiac motion leads to an inaccurate T1 mapping. Therefore, registration is needed. However, standard registration methods are computationally expensive. To overcome this challenge, we propose a new deep-learning-based group-wise registration approach that register all the different time points simultaneously. Our approach achieved the best median model-fitting R 2 compared to baseline methods (0.9846, vs. 0.9651/0.9744/0.9756), and achieve reasonably close T1 value to the expected myocardial T1 value |
| 4974.
 | 28 | Improving cardiac cine MRI using a deep learning-based ESPIRiT reconstruction with self attention Terrence Jao1, Christopher Sandino2, and Shreyas Vasanawala1 1Department of Radiology, Stanford University, Stanford, CA, United States, 2Department of Electrical Engineering, Stanford University, Stanford, CA, United States Keywords: Heart, Machine Learning/Artificial Intelligence, Deep Learning, Unrolled, Self Attention, CINE A deep learning based ESPIRiT
(DL-ESPIRiT) was recently proposed to reconstruct dynamic MRI data with higher
reconstruction accuracy. However, the method still has difficulty resolving
fine anatomic structures. We propose incorporating self-attention to the
network using a computationally lightweight squeeze-excitation block
(DL-ESPIRiT SE), which uses global information to select more important
features while suppressing less important ones. We demonstrate improved reconstruction
with DL-ESPIRiT SE, which is most pronounced during faster
cardiac motion such as in ventricular ejection. |
| 4975.
 | 29 | 2D U-Net based myocardium segmentation for quantitative sequences with limited data: demon co-registration approach Habib Rebbah1 and Timothé Boutelier1 1Research & Innovation, Olea Medical, La Ciotat, France Keywords: Myocardium, Segmentation Obtaining databases with expert’
manual segmentations to train U-Net is an essential but also a time-consuming operation.
We explore here the effect of expanding such a database to other cases with a
demon co-registration algorithm. The purpose is to speed up the manual steps
but also to allow the development of segmentation algorithms for new cases. We
illustrate our approach with MOLLI’ masks expanded to T2 and perfusion data. |
| 4976.
 | 30 | Automatic catheter tracking during cardiac MRI guided cardiac catheterization using deep learning Alexander Paul Neofytou1, Grzegorz Tomasz Kowalik1, Radhouene Neji1,2, Reza Razavi1, Kuberan Pushparajah1, and Sébastien Roujol1 1School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom, 2MR Research Collaborations, Siemens Healthcare Limited, Camberley, United Kingdom Keywords: Heart, MR-Guided Interventions A
deep neural network trained on images with artificially generated catheter
signal was developed and enables accurate detection of catheter signal under
real-time conditions. Further investigations, with in-line integration, are now
warranted to determine the benefit of this technique for improved catheter
navigation. |
| 4977.
 | 31 | Correcting motion-induced B0 shim failure at 3T CMR using a deep-learning-enabled 3D motion-resolved B0 shimming Xinqi Li1, Yuheng Huang2, Xingmin Guan2, Xinheng Zhang2, Ghazal Yoosefian2, Xiaoming Bi3, Fei Han3, HsuLei Lee1, Anthony Christodoulou1, Debiao Li1, Rohan Dharmakumar2, Hui Han1, and Hsin-Jung Yang1 1Biomedical Image Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States, 2Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, IN, United States, 3Siemens Healthineers, Malvern, PA, United States Keywords: Myocardium, Shims B 0 inhomogeneity is a long-lasting issue for CMR in high-field (3T and above) scanners. B 0 shimming is a standard way to improve the B 0 field. However, motion-induced field inhomogeneity is an unknown factor in routine practice and compromises cardiac B 0 shimming quality. Here, we proposed a motion-resolved cardiac B 0 shimming strategy by acquiring motion-resolved cardiac B 0 field maps and adopting a modified U-net model for precise and automatic shim field derivation. We showed that dynamic shimming could improve field homogeneity through the respiratory cycle and provide a reliable B 0 field for free-breathing CMR at 3T. |
| 4978.
 | 32 | Detection and tracking enhancement using 4-channels local standalone resonators for catheterized interventional MRI at 3T Komlan Payne1, Yunkun Zhao1, Leslie L. Ying1, and Xiaoliang Zhang1 1Department of Biomedical Engineering, University at Buffalo, Buffalo, NY, United States Keywords: Vessel Wall, Interventional Devices, Blood vessels Catheter-based RF coils are preferred over conventional external coils due to the weak detection signal from intermediate field region. One of the major issues using catheter RF coils is the design payload (feeding network, preamplifier, balun) associated with the limited space of the catheter. The technique also lacks efficient way to track the catheter during the procedure. To overcome these challenges, we propose 4-channel standalone and wireless resonators to amplify the local B1 field while a body coil is used as the transceiver. The receive B1 fields with and without the local resonators are obtained for field enhancement analysis. |
| 4979.
 | 33 | Patient specific respiratory motion correction for cardiac MRI Jiameng Diao1, Yang Liu1, Wenjian Liu1, Yiming Tao1, Jianing Geng1, Shang Cao1, Jiayu Zhu2, Junpu Hu2, Jian Xu3, Zijian Zhou1, Haikun Qi1,4, and Peng Hu1,4 1School of Biomedical Engineering, ShanghaiTech University, Shanghai, China, 2United Imaging Healthcare, Shanghai, China, 3UIH America, Inc., Houston, TX, United States, 4Shanghai Clinical Research and Trial Center, Shanghai, China Keywords: Heart, Motion Correction Magnetic resonance imaging (MRI) is susceptible
to respiratory motion-induced artifacts due to the relatively slow data
acquisition. These artifacts remain an impediment to clinical application and are
further amplified in cardiovascular MRI. Respiratory motion model is an
effectively method to reduce motion artifacts. In this study, we proposed a
novel patient-specific respiratory motion correction method with more reliable
training data and capability to perform spoke-wise correction. Combined with
compressed sensing, parallel imaging, image registration and model fitting, this
method greatly reduces respiratory motion artifacts. |
| 4980.
 | 34 | Spherical harmonic shim analysis of B0 distributions in cardiac imaging planes from 921 subjects Yun Shang1, Sebastian Theilenberg1, Boyu Peng2, Michael Hock3, Laura M. Schreiber3,4, Sachin Jambawalikar1,2, and Christoph Juchem1,2 1Department of Biomedical Engineering, Columbia University in the City of New York, New York, NY, United States, 2Department of Radiology, Columbia University in the City of New York, New York, NY, United States, 3Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure Center (CHFC), Würzburg, Germany, 4Section of Medical Physics, Department of Radiology, Mainz University Hospital, Mainz, Germany Keywords: Heart, Shims Cardiac functional scans adopting bSSFP sequences suffer from
dark band artifacts due to B 0 inhomogeneity. The best remedy to
mitigate this issue is through cardiac B 0 shimming. A limited
understanding of the B 0 conditions in clinical diagnostic
orientations impedes the development of an optimal B 0 shim strategy
in the human heart. Here we perform a theoretical analysis of spherical harmonic B 0
shim at 3 T using a static global approach and slice-specific dynamic
shim updating in the short-axis views of human hearts from 921 subjects as a
starting point for the development of optimized cardiac B 0 shim
strategies. |
| 4981.
 | 35 | Accelerated, Free-Breathing 3D Cardiac T1ρ Mapping Pulse Sequence with XD-GRASP Reconstruction Suvai Gunasekaran1, KyungPyo Hong1, Roberta Catania1, Joshua Robinson2, Rod Passman3, Aggelos Katsaggelos4, Cynthia Rigsby5, Walter Witschey6, and Daniel Kim1 1Radiology, Northwestern University, Feinberg School of Medicine, Chicago, IL, United States, 2Cardiology, Lurie Children’s Hospital, Chicago, IL, United States, 3Cardiology, Northwestern University, Feinberg School of Medicine, Chicago, IL, United States, 4Electrical and Computer Engineering, Northwestern University, Evanston, IL, United States, 5Radiology, Lurie Children’s Hospital, Chicago, IL, United States, 6Radiology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, United States Keywords: Myocardium, Quantitative Imaging, Fibrosis T1ρ
mapping is an emerging non-contrast pulse sequence for measuring cardiac
fibrosis. Unfortunately, current T1ρ techniques suffer from lack of coverage,
poor spatial resolution, and long scan time. Thus, we developed an accelerated,
free-breathing 3D cardiac T1ρ mapping pulse sequence using XD-GRASP
reconstruction including both respiratory and contrast dimensions;
additionally, view sharing and KWIC filtering were incorporated to improve
spatial resolution. This sequence was tested in 8 patients undergoing
clinically indicated cardiac MRI, resulting in robust image quality and T1ρ
values that are in agreement with literature.
|
| 4982.
 | 36 | Dual-Band Adiabatic Pulses in cardiac MRI: Application in Black Blood Imaging at 3T Ayda Arami1, Christal van de Steeg-Henzen2, Hildo J.Lamb3, and Sebastian Weingärtner1 1TU Delft, Delft, Netherlands, 2HollandPTC, Delft, Netherlands, 3LUMC, Leiden, Netherlands Keywords: Myocardium, RF Pulse Design & Fields Black-Blood imaging is an integral part of clinical cardiac MRI, due to it’s clear depiction of the cardiac morphology. Double inversion recovery, is most commonly used for black-blood contrast, by successively applying a non-selective inversion and a slice-selective reinversion. In this work, we investigate dual band adiabatic inversion pulses, as an alternative, to achieve nulling of the blood signal outside of the imaging slice. Thorough blood suppression and comparable noise performance to double inversion recovery were demonstrated in vivo while achieving an 11% reduction in SAR and a 10% reduction in pulse duration. |
| 4983.
 | 37 | Ultrahigh Field CMR for the Assessment of Cardiac Function – Scan Rescan Reproducibility and Shim Limitations David Lohr1, Wiebke Schlötelburg2, Maxim Terekhov1, and Laura Maria Schreiber1 1Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, Würzburg, Germany, 2Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany Keywords: Myocardium, High-Field MRI In this study we
aim to analyze blood tissue contrast (BTC), SNR, and reproducibility in
measurements of cardiac function at 7T. Furthermore, we assess shim quality and
its impact on image quality as well as T 2*. Measurements are performed in n=7 healthy volunteers using a 7T system.
Diastolic BTC and SNR in scan1 and scan2
were 2.14±0.24 and 2.22±0.33 as well as 96±35 and 105±29, respectively.
Reproducibility assessed via intra class correlation coefficient was found to
be excellent for ejection fraction (0.93), myocardial mass (0.99), stroke
volume (0.91), end-systolic volume (0.94), and end-diastolic volume (0.93). |
| 4984.
 | 38 | Off-resonance encoded fat suppression methods for 5D whole-heart free-running cardiac MRI at 1.5T Yasaman Safarkhanlo1,2, Jerome Yerly3,4, Mariana Falcao3, Adèle LC Mackowiak2,3,5, Davide Piccini3,6, Matthias Stuber3,4, Bernd Jung2,5, Christoph Gräni1,2, and Jessica AM Bastiaansen2,5 1Department of Cardiology, University Hospital Bern, Inselspital, Bern, Switzerland, 2Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland, 3Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Lausanne, Switzerland, 4Center for Biomedical Imaging, Lausanne, Switzerland, 5Diagnostic, Interventional and Pediatric Radiology (DIPR), University Hospital Bern, Inselspital, Bern, Switzerland, 6Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland Keywords: Heart, Fat, data acquisition, data analysis, image reconstruction, low-field MRI The presence of fat signals around the heart can affect the diagnostic quality of cardiovascular MR images. There are multiple fat-suppression pulses, such as FISS, and off-resonance water-excitation (WE) pulses, such as BORR, LIBRE, and LIBOR, that have been developed for the free-running balanced Steady-State Free-Precession (bSSFP) sequences at low-field MRI (1.5T). These fat-suppression pulses have never been thoroughly compared to each other, therefore, in this work, we implemented four different fat-suppression pulses and validated their performance on phantoms and healthy volunteers. Our results indicated LIBOR provided better fat suppression compared to BORR and LIBRE, while having fast acquisition time. |
| 4985.
 | 39 | Recovering image orientation for unconventional acquisition plane with deep learning algorithm: cardiac magnetic resonance case. Habib Rebbah1 and Timothé Boutelier1 1Research & Innovation, Olea Medical, La Ciotat, France Keywords: Myocardium, Segmentation Deducing the orientation main
view of an image from the DICOM information could be complicated especially for
unconventional image plane as for cardiac MR. We explore here the feasibility of
deducing the orientation of the image based on CNN approach. |
| 4986.
 | 40 | A clinical application of deep learning reconstructed myocardial late gadolinium enhancement on short-breath-hold patients Xuefang Lu1, Weiyin Vivian Liu2, Yuchen Yan1, Changsheng Liu1, Wei Gong1, Yan Wang1, Yilin Zhao1, Guangnan Quan3, and Yunfei Zha1 1Department of Radiology, Renmin Hospital of Wuhan University, Wuhan, China, 2GE Healthcare, MR Research China, Beijing, China, 3General Electric Medical (China) Co, Beijing, China Keywords: Myocardium, Image Reconstruction SNR and CNR are essential for radiologists to precisely
assess the signal enhancement in myocardia tissues. High-resolution late
gadolinium enhancement cardiac magnetic resonance (LGE-CMR) is important
but often possess low SNR and takes long scan time. Compared with original PSMDE (PSMDE O), AIRTM Recon DL-based PSMDE (PSMDE DL)
effectively and significantly improved SNR, CNR and image quality without extra
scan time. High-resolution PSMDE DL images also accelerated diagnossis
speed of identifying defected tissues from noisy but normal myocardial tissues and
elevated the diagnosis confidence despite no statistically different diagnostic
performance between PSMDE DL and PSMDE O images. |